Meter Wiring Diagram 400 Amp
The use of a transocket cts in switchgear see subsections 5 6 and 5 7 or overhead ct metering see subsection 5 8.
Meter wiring diagram 400 amp. Meter base ground must be unbroken from ground rod to ground connection in base. The electric compnay is running a single 400 amp line to the meter. Energized by the challenge of powering up a world that eaton s electrical business. I am running 400 amp service into my new contruction home.
A detailed video over milbank s 400 amp meter main product options. Assortment of volt amp meter wiring diagram. How to wire a house main electrical panel load center layout tips full step by step process 200amp duration. Use the flashlight or drop light to see the wiring under the dash.
I will need the local power company to upgrade the drop to 320 amps. What meter base will be appropriate for this change and are there any other issues i need to be concerned about to comply with codes. It reveals the elements of the circuit as simplified forms and the power and signal connections between the devices. Use the wiring diagram and test light or multi meter to locate the positive wire from the alternator to the fuse block.
This meter main is designed for larger residential and commercial applications and provides both a meter socket and main breaker. Ct metering is required for 400 amp and larger single phase 400 amp and larger 120 208 three phase and 400 amp and larger 277 480 three phase. Meter mounting distribution equipment. 400 amp meter base correct wiring diagram.
Ground wire must be in 1 2 thin wall conduit or 1 2 grey electrical pvc. Benjamin sahlstrom 949 668 views. A wiring diagram is a simplified traditional photographic representation of an electric circuit. Important wiring information consumer wires to straight load buss spades remc wires to curved line buss spades neutral wire buss spades 4 copper to ground rod spade.
You had told me once before that i need a 320 amp meter socket and then run 2 200 amp lines to the separate panels inside. Pvc conduit can only be used on the load side of the disconnect box. Then locate any wire that has power with the ignition off. Be sure to brace guy or concrete service pole 8 ground rod with approved ground rod clamp switch box conduit hot wire neutral lightning size size size size ground 400 amp 3 or 2 2 500mcm 1 250mcm 1 1 0 only copper wire type thhn or.
I have to split it to the two panels at that point. I need to replace a 200 amp meter base with a 400 amp base splitting off 200 amps to my house and 200 amps to a new shop.